Multiparameter Photometer & pH Meter

R32,558.00

Weight 2 kg
Dimensions 20 × 20 × 20 cm
wws Got a question? / Not sure of something? Chat an Expert via WhatsApp
Description
multiparameter photometer & ph meter

Multiparameter Photometer & pH Meter for Water Conditioning- HI83308-02

HI83308 is a compact, multiparameter photometer for use in water conditioning applications.

The meter is one of the most advanced photometers available with a innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette.

This meter has 23 different programmed methods measuring 15 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves. Water conditioning parameters include fluoride, chlorine, ammonia, manganese, copper, iron, silver and zinc.

To save valuable laboratory benchtop space, the HI83308 doubles as a professional pH meter with its digital pH/temperature electrode input. Now one meter can be used for both photometric and pH measurements.

pH RangePhotometer: 6.5 to 8.5 pH
pH electrode: -2.00 to 16.00 pH
pH ResolutionPhotometer: 0.1 pH
pH electrode: 0.01 pH
pH AccuracyPhotometer: ±0.1 pH
pH electrode: ±0.01 pH
pH CalibrationAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)
pH Temperature CompensationAutomatic (-5.0 to 100.0 oC; 23.0 to 212.0 oF); limits reduced based on the pH electrode used
pH CAL Check (electrode diagnostics)clean electrode and check buffer/check probe displayed during calibration
pH MethodPhotometer: phenol red
pH-mV Range±1000 mV
pH-mV Resolution0.1 mV
pH-mV Accuracy±0.2 mV

Oxygen, Dissolved

Oxygen, Dissolved Range0.0 to 10.0 mg/L (as O2)
Oxygen, Dissolved Resolution0.1 mg/L
Oxygen, Dissolved Accuracy±0.4 mg/L ±3% of reading
Oxygen, Dissolved MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method

Absorbance

Absorbance Range0.000 to 4.000 Abs
Absorbance Resolution0.001 Abs
Absorbance Accuracy+/-0.003Abs @ 1.000 Abs

Ammonia

Ammonia RangeLow Range: 0.00 to 3.00 mg/L
Medium Range: 0.00 to 10.00 mg/L
High Range: 0.0 to 100.0 mg/L
(all as NH3-N)
Ammonia Resolution0.01 mg/L; 0.1 mg/L
Ammonia AccuracyLow Range: ±0.04 mg/L ±4% of reading
Medium Range: ±0.05 mg/L ±5% of reading
High range: ±0.5 mg/L ±5% of reading
Ammonia MethodAdaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method

Chlorine

Free Chlorine Range0.00 to 5.00 mg/L (as Cl2)
Free Chlorine Resolution0.01 mg/L
Free Chlorine Accuracy±0.03 mg/L ±3% of reading
Total Chlorine Range0.00 to 5.00 mg/L (as Cl2)
Total Chlorine Resolution0.01 mg/L
Total Chlorine Accuracy±0.03 mg/L ±3% of reading
Chlorine MethodAdaptation of the EPA 330.5 DPD method

Copper

Copper RangeLow Range: 0.000 to 1.500 mg/L (as Cu2+)
High range: 0.00 to 5.00 mg/L (as Cu2+)
Copper Resolution0.001 mg/L; 0.01 mg/L
Copper AccuracyLow Range: ±0.01 mg/L ±5% of reading
High Range ±0.02 mg/L ±4% of reading
Copper MethodAdaptation of the EPA bicinchoninate method

Fluoride

Fluoride Range0.00 to 2.00 mg/L (as F-)
Fluoride Resolution0.01 mg/L
Fluoride Accuracy±0.03 mg/L ±3% of reading
Fluoride MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method

Iron

Iron RangeLow Range: 0.000 to 1.600 mg/L (as Fe)
High Range: 0.00 to 5.00 mg/L (as Fe)
Iron Resolution0.001 mg/L; 0.01 mg/L
Iron AccuracyLow Range: ±0.01 mg/L ±8% of reading
High Range: ±0.04 mg/L ±2% of reading
Iron MethodLow Range: Adaptation of the TPTZ Method
High Range: Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters

Manganese

Manganese RangeLow Range: 0 to 300 ?g/L (as Mn)
High Range: 0.0 to 20.0 (as Mn)
Manganese Resolution1 ?g/L; 0.1 mg/L
Manganese AccuracyLow Range: ±10 ?g/L ±3% of reading
High Range: ±0.2 mg/L ±3% of reading
Manganese MethodLow Range: Adaptation of the PAN Method
High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method

Molybdenum

Molybdenum Range0.0 to 40.0 mg/L (as Mo6+)
Molybdenum Resolution0.1 mg/L
Molybdenum Accuracy±0.3 mg/L ±5% of reading
Molybdenum MethodAdaptation of the mercaptoacetic acid method

Nickel

Nickel RangeLow Range: 0.000 to 1.000 mg/L (as Ni)
High Range: 0.00 to 7.00 g/L (as Ni)
Nickel Resolution0.001 mg/L; 0.01 g/L
Nickel AccuracyLow range: ±0.010 mg/L ±7% of reading
High Range: ±0.07 g/L ±4% of reading
Nickel MethodLow Range: Adaptation of the PAN method
High Range: Adaptation of the photometric method

Nitrate

Nitrate Range0.0 to 30.0 mg/L (as NO3– N)
Nitrate Resolution0.1 mg/L
Nitrate Accuracy±0.5 mg/L ±10% of reading
Nitrate MethodAdaptation of the cadmium reduction method

Phosphate

Phosphate RangeFreshwater
Low Range: 0.00 to 2.50 mg/L (as PO43-)
High range: 0.0 to 30.0 mg/L(as PO43-)
Phosphate Resolution0.01 mg/L; 0.1 mg/L
Phosphate AccuracyLow Range: ±0.04 mg/L ±4% of reading
High Range: ±1 mg/L ±4% of reading
Phosphate MethodLow Range: Adaptation of the Ascorbic Acid method
High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method

Silica

Silica Range0.00 to 2.00 mg/L (as SiO2)
Silica Resolution0.01 mg/L
Silica Accuracy±0.03 mg/L ±3% of reading
Silica MethodAdaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method

Silver

Silver Range0.000 to 1.000 mg/L (as Ag)
Silver Resolution0.001 mg/L
Silver Accuracy±0.020 mg/L ±5% of reading
Silver MethodAdaptation of the PAN method

Zinc

Zinc Range0.00 to 3.00 mg/L (as Zn)
Zinc Resolution0.01 mg/L
Zinc Accuracy±0.03 mg/L ±3% of reading
Zinc MethodAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method

General Meter

Input Channels1 pH electrode input and 4 photometer wavelengths
pH Electrodedigital pH electrode (not included)
Logging Typelog on demand with user name and sample ID optional input
Logging Memory1000 readings
ConnectivityUSB-A host for flash drive; micro-USB-B for power and computer connectivity
GLPcalibration data for connected pH electrode
Display128 x 64 pixel LCD with backlight
Battery Type / Life3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
Power Supply5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Environment0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing
Dimensions206 x 177 x 97 mm (8.1 x 7.0 x 3.8″)
Weight1.0 kg (2.2 lbs.)
Photometer/Colorimeter Light Source4 LEDs with 420 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters
Photometer/Colorimeter Light Detectorsilicon photodetector
Bandpass Filter Bandwidth8 nm
Bandpass Filter Wavelength Accuracy±1 nm
Cuvette Typeround, 24.6 mm
Number of Methods128 max.
Ordering InformationHI83308 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.

 

 